Sample Preparation
Homogenization
Heating and Mixing
Electrophoresis and Blotting
Polyacrylamide Gel Electrophoresis
Agarose Gel Electrophoresis
Western Blotting
Power Supplies
PCR & qPCR Thermal Cycler
Thermal Cycler (PCR)
Real-time Thermal Cycler (qPCR)
PCR Workstations & Cabinets
UVP BioImaging Systems
Molecular Spectroscopy
Lab Equipment
Ultraviolet Products
Hybridization Ovens
UVP Incubator
UV Crosslinkers
UVP Benchtop Transilluminators
Thermal Mixers
Electrophoresis & Blotting
Thermostats
View All
Fume hood
Laminar Airflow
Biosafety Cabinet
Autoclave
Centrifuge
pH Meter
Shaker & Mixer
Orbital Shaking Incubator
BOD Incubator
Heating Oven
Water Purification System
Aermax - Air Purification
Medical Oxygen Concetrators
Hygiene Solution
-150°C Cryogenic Freezer
-86°C Ultra Low Temp Freezer
-40°C Low Temp Freezer
-18 ~ -25°C Biomedical Freezer
-20°C Biomedical Freezer
4° ± 1°C Blood Bank Refrigerators
2~8°C Pharma Refrigerators
2~8°C ICE Lined Refrigerators
-25°C ~ + 4°C Mobile Freezer/Collers
20~24°C Blood Platelet Incubators
Ice Machines
Coldrooms
Mortuary Chambers
Sample Homogenization. Powerful and Reproducible.
Achieving high quality results starts with careful sample preparation including efficient and reproducible sample homogenization. The SpeedMill PLUS meets these requirements and forms the foundation for your successful analysis.
The homogenization process by SpeedMill PLUS is based on an innovative double action technology - a mechanical principle for which a patent has been filed. This new process allows users to operate the SpeedMill PLUS continuously if necessary, whereby efficient sample cooling is facilitated by the holder, which can be stored at down to -80 °C. The compact design, intuitive use interface and availablity of pre-defined protocols are decisive for the ease of use.
The SpeedMill PLUS is a highly efficient homogenization system for various starting materials used for the subsequent isolation and purification of DNA, RNA or proteins. The homogenization process is based on an innovative mechanical principle for which a patent has been filed. This new process allows users to operate the SpeedMill PLUS continuously if necessary. The high efficiency of energy input into the sample, based on a vertical movement, procures a homogeneous disruption of the sample without destroying the target molecules.
For the optimized sample holder, which is used inside the SpeedMill PLUS, different temperature ratings are freely selectable due to the storage down to –80 °C. According to this an efficient sample cooling during the whole homogenization process is warranted and the substantial sample warming that occurs with other homogenizers is prevented. The often problematic handling of liquid nitrogen or dry ice is thus a thing of the past. Additionally the considerably expense factor of this additives, which have to be loaded continuously, is not applicable. Besides the sample holder allows an easy transport of the sample tubes and a long term storage of starting or homogenized material at adequate temperatures.
The samples to be processed are rapidly and efficiently homogenized in Lysis Tubes that have been specially optimized for the system and, as such, contain different and/or application-specific beads. Using beads makes it possible to completely and reproducibly homogenize even the toughest starting materials, such as cartilage and chitin shells of insects or ticks within a very short time. 2.0 ml and 0.5 ml containers (Lysis Tubes) with different beads are available for sample preparation, allowing users to adapt sample processing to a diverse range of soft and hard starting materials. Operating processes, such as loading and removing of the sample tubes, are very simple and no tools are required. In addition userdefined protocols can be entered and saved as well as pre-installed programs are available. Homogenization parameters, like time and using cyclic routines are freely selectable.
Digestion using SpeedMill PLUS is based on an innovative, patented mechanical principle and ensures highly efficient energy input. Based on a vertical movement, the process also ensures that the samples are homogeneously digested without destroying the target molecules.
Entire and reproducible homogenizing of up to 20 samples
Efficient sample cooling during the whole preparation without need for cost-intensive consumables
Flexible homogenizing system for various starting materials
Innovative double action technology
Passive sample cooling to -80°C
Pre-defined protocols
No acceleration/deceleration times
Compact design and minimal footprint
Contact us for expert advice for your needs and budget.
Homogenization time
Programmable homogenization step
Number of cycles
Protocol steps
Storable protocols
Sample cooling
Steps of adjusting time
Pre-programmed protocols
User-defined protocols
Sample capacity
Acceleration time
Deceleration time
Homogenization routines
Device handling
Sample handling
SpeedMill PLUS 110 V845-00007-4
SpeedMill PLUS 230 V845-00007-2