Product Details

Diode array spectrophotometer for working in the UV- and Vis-range

The UV/Vis spectrophotometer SPECORD S 600 combines the precision and convenient handling needed in laboratories with speed, reliability and superior optical performance. This simultaneous high-performance diode array spectrophotometer works precise, fast, simultaneous.

The analytical advantages
  • High precision polychromator systems – permanently adjusted and fixed with no moving parts
  • Open sample compartment which accommodates all available accessories of the SPECORD S 600
  • Excellent spectral properties, fast measurement of complete spectra in less than 12 milliseconds
  • Life Sience package for measurements of small sample volumes, determination of DNA/RNA (additional module)
  • Self adjusting photometric linearity
  • Automatic stray light correction
  • Easily accessible and interchangeable light sources
  • Self Check System (SCS)

The MCS (Multi Channel System) optics has proven its worth based on lasting dependability in laboratory analysis as well as process analysis.

High-precision optics

The polychromator systems, designed to work without any movable components, are the heart of the SPECORD S 600. The high-precision optics consists of an aberration-corrected grating, a mechanical slit and the diode array detector. Encased in a rugged quartz-ceramic body, it is permanently adjusted, fixed and insensitive to external influences. This design ensures extremely accurate and highly reproducible results. At the same time, SPECORD S 600 provides all the flexibility needed to solve most analytical problems. Ruggedness, thermal stability as well as their high light yield are additional advantages of this device.

High-speed spectrometer

With a minimum scan rate of 12 milliseconds the SPECORD S 600 offers extremely fast analyses.

Analytik Jena
SPECORD S 600

Precision

Convenient Handling

Speed

Reliability

Need Assistance?

Contact us for expert advice for your needs and budget.

Accessories
  • Standard cell holder, 50 mm
  • Cell holder, 100 mm
  • Holder for cylindrical cells up to 50 mm
  • Holder for cylindrical cells up to 100 mm
  • Holder for absorption tubes
  • Universal holder for accommodation of accessories
  • Cell holder, thermostatted, up to 50 mm
  • Cell holder, up to 10 mm, thermostatted without/with stirrer
  • Round cell holder for testkits
  • Solid sample holder
  • Adjustable cell holder for small cells aligned to the sample beam with path length 10 mm with beam height 15 and 8.5 mm
  • Adjustable cell holder for small cells aligned to the sample beam with path length 1/2/5/10 mm with beam height 8.5 mm
  • Fibre optical ultra micro cell/TrayCell
  • Peltier cooled cell holder with stirrer -5 °C–105 °C
  • Peltier cooled cell holder with stirrer 10 °C– 60 °C
  • Peltier cooled cell holder with stirrer, external heat exchanging -5 °C–105 °C
  • 6 cell changer for 10, 20, 40, 50 mm pathlength
  • 6 cell changer for 10 mm pathlength, water thermostatted without stirrer/with stirrer
  • 6 cell changer for 10 mm pathlength, Peltier cooled 10 °C–60 °C and external heat exchanging
  • 8 cell changer without stirrer/with stirrer for 10 mm pathlength, not thermostatted, water thermostatted, Peltier cooled, -5 °C–105 °C and external heat exchanging
  • Cassette sipper system with adjustable cell holder for 10/20/40/50 mm pathlength
  • xyz autosampler APG 64 with sample racks for 53 or 100 vials
  • Cell Carousel, not thermostatted, without stirrer, 15 places for cells 10 mm pathlength
  • Diffuse reflectance accessory with integrating sphere
  • 11°–60° variable angle reflectance accessory
  • Absolute reflectance accessory
  • Fiber coupling set UV
  • Fiber coupling set QX
  • Fiber coupling set SMA
  • Standard immersion probe
  • Fully automatic cell carousel with 52 positions
Cell holder
  • Standard cell holder, 50 mm
  • Cell holder, 100 mm
  • Holder for cylindrical cells
  • Holder for absorption tubes
  • Universal holder for accommodation of accessories
  • Cell holder, 50 mm pathlength, thermostatted
  • Cell holder, 10 mm pathlength, thermostatted without/with stirrer
  • Round cell holder
  • Solid sample holder
  • Adjustable cell holder for small cells aligned to the sample beam with pathlength 10 mm 
  • Holder for small cells, adjustable accommodation of small cells exactly aligned to the sample beam with pathlength 1/2/5/10 mm 
  • Peltier cooled cell holder, air-colled
  • Cell holder peltier cooled  with stirrer and external heat exchanging
Miscellaneous
  • Cell Carousel with 15 vials, not thermostatted
  • Cassette sipper system 
  • xyz autosampler APG basic with sample racks for 49, 64 or 116 vials
  • Diffuse reflectance accessory with integrating sphere
  • 11° – 60° variable angle reflectance accessory
  • Angle accessory for absolute reflectance
  • SMA and collimator fiber coupling
  • Standard immersion probe
Cell changer

The 6-cell changer is available in the following configurations

  • Cell changer for cuvettes with variable layer thickness, sample block for cuvettes with 10, 20, 40 and 50 mm thickness, no temperature control, without stirring fucntion
  • Cell changer for cuvettes with 10 mm layer thickness, temperature control via external thermostats
  • Cell changer for cuvettes with 10 mm layer thickness, temperature control via external thermostats and with magnetic stirring function
  • Peltier temperature controlled cell changer with or without magnetic stirring function

The following additional options are available for the 8-cell changers:

  • Magnetic stirring function
  • Temperature control with external thermostats
  • Peltier temperature controlled with or without magnetic stirring function

Cell Carousel with 15 vials, not thermostatted

Review
Average Rating: 0.0
0 Peoples have reviewed this product

Ease of use
After sales service
Value for money

More Products

Recent Blogs

What is Surface Plasmon Resonance (SPR)? How does SPR work?

What is Surface Plasmon Resonance (SPR)? How does SPR work?

Read More
Basis of Spectrophotometry

Basis of Spectrophotometry

Read More
Spectrophotometer and Spectrometer

Spectrophotometer and Spectrometer

Read More

Popular Blogs

Principle of UV - Vis Spectroscopy

Principle of UV - Vis Spectroscopy

Read More
Factors Affecting UV-Vis Spectroscopy

Factors Affecting UV-Vis Spectroscopy

Read More
UV-Vis Spectrophotometer- Applications

UV-Vis Spectrophotometer- Applications

Read More