Sample Preparation
Homogenization
Heating and Mixing
Electrophoresis and Blotting
Polyacrylamide Gel Electrophoresis
Agarose Gel Electrophoresis
Western Blotting
Power Supplies
PCR & qPCR Thermal Cycler
Thermal Cycler (PCR)
Real-time Thermal Cycler (qPCR)
PCR Workstations & Cabinets
UVP BioImaging Systems
Molecular Spectroscopy
Lab Equipment
Ultraviolet Products
Hybridization Ovens
UVP Incubator
UV Crosslinkers
UVP Benchtop Transilluminators
Thermal Mixers
Electrophoresis & Blotting
Thermostats
View All
Fume hood
Laminar Airflow
Biosafety Cabinet
Autoclave
Centrifuge
pH Meter
Shaker & Mixer
Orbital Shaking Incubator
BOD Incubator
Heating Oven
Water Purification System
Aermax - Air Purification
Medical Oxygen Concetrators
Hygiene Solution
-150°C Cryogenic Freezer
-86°C Ultra Low Temp Freezer
-40°C Low Temp Freezer
-18 ~ -25°C Biomedical Freezer
-20°C Biomedical Freezer
4° ± 1°C Blood Bank Refrigerators
2~8°C Pharma Refrigerators
2~8°C ICE Lined Refrigerators
-25°C ~ + 4°C Mobile Freezer/Collers
20~24°C Blood Platelet Incubators
Ice Machines
Coldrooms
Mortuary Chambers
THE SMART UV-VIS SPECTROPHOTOMETER
OPTIZEN POP SERIES are single-beam type spectrophotometers and offer stable performance and compact-size and reasonable price to the users.
The series are categorized into POP, POP-S, POP-V according to the specification of the products.
OPTIZEN POP offers four measurement modes (Photometric Mode, Quantitative Mode, Spectrum Mode, Kinetics Mode).
The user can choose a suitable mode depending on the purpose to measure.
The embedded S/W, touch screen interface and application facilitate the use of the device.
Contact us for expert advice for your needs and budget.
Experience faster and more convenient OPTIZEN POP.
THE BEST VISUAL
AND FUNCTIONAL EXPERIENCE
OPTIZEN POP has an intuitive interface that allows accurate data measurement and analysis with a single touch, focusing on user convenience. The measurement results are also easy to be edited and exported. The POP includes a variety of features optimized for laboratory equipment.
By registering the information that is being measured or analyzed, or has been completed, you can easily and quickly call up the information to perform tasks.
You can always check measured values in real time.
Measurement monitoring is possible by selecting a cell type without entering the mode. The icon of the cell type in the quick menu changes according to the cell type status or position, so that the current status of the cell can be easily checked.
You can check the operating time of the equipment, the preheating status of the lamp and the cumulative operating time in real time and measure in the optimal status.
Measured data are saved in the extended memory by default to prevent data loss due to equipment damage. They can also be saved in an external device by using the backup function.
By providing a drag-select method, it is possible to set a magnification range, and the user can easily enlarge the desired section. The auto-scale function is implemented.
OPTIZEN Pop can be directly measured from the instrument or remotely from a PC. In a network environment, analysis results can be viewed on a PC without a limit of work space.
By storing data in the extended memory and USB, the user can perform various tasks such as switching data, applying special conversion expressions and exporting to Excel in PC.
The volume of the instrument (16 levels) can be adjusted to suit the laboratory environment.
Modes for Measurement
THE UNCOMPROMISING
PERFORMANCE
OPTIZEN POP is equipped with an 8-position rotary multi-cell holder as standard which minimizes the impact of light source drift by measuring the blank automatically of each sample measurement.
OPTIZEN POP employed the company’s own high resolution wavelength measurement mechanism. This mechanism guarantees a wavelength reproducibility of less than 0.1 nm in all bands. The wavelength accuracy verified through the Holmium Oxide filter (MU* = ±0.2 nm) and Didymium Filter (MU* = ±0.2 nm) is ±0.5 nm or less.
OPTIZEN POP automatically adjusts the baseline at each measurement, providing a constant baseline flatness without additional baseline correction.
Since OPTIZEN POP uses a single-beam monochromator, fluctuations in the measured values may occur due to the drift phenomenon of the light source immediately after turning on the equipment. This phenomenon is gradually stabilized through a preheating process of the light source. Therefore, it is recommended to preheat for more than one hour for high-precision measurement, and in this case, the stability within 0.001 Abs is guaranteed.
OPTIZEN Alpha guarantees photometric accuracy of less than ±0.005 Abs (at 1.0 Abs) and photometric repeatability of less than ±0.0006 Abs(at 1.0 Abs) with exceptional noise characteristics.