Air Purification system is a portable, self-contained ULPA filtration system (1st of its kind) designed to easily and economically create a world class Indoor Air Quality environment that will meets the best of OSHA, CDC and NABH guidelines.

Key Features

  • ULPA Filtration System
  • Odor Eliminating KMNO4/ Activated Carbon Filteration (optional)
  • Germicidal UV light
  • Needle Point / Brush Bipolar Ionisation - Zero Ozone Emissions as per UL2998 Validation
  • Multi Angle Air Diffusion
  • World Class EC Blower
  • Speed regulation for lower power consumption
  • IBMS Compatible for control and data logging , RS 485 connectivity
  • Plug and Play, Portable
  • Silver Ion Coating on the inner plenum for reduction of Bio Burden (optional)

AS POSITIVE PRESSURE EQUIPMENT

Air Purification system can be used as a positive pressure clean air circulating system in Clinics, waiting rooms, hospital emergency rooms and other confined areas.

AS A RECIRCULATING EQUIPMENT

Air Purification system’s powerful motor/blower can deliver from 800 to 2000 CFM to provide a large number of room air changes per hour to minimize the spread of airborne infections to patients and health care workers. It helps in maintaining Air Quality in varied applications like Class rooms, Health Care sector, Corporate offices, Hotels, etc

AS NEGATIVE PRESSURE EQUIPMENT

As a negative pressure unit, the air passing the ULPA filter is cleansed of 99.9997% of particles as small as 0.12 micron and may be exhausted directly to the exterior . It can be used as partial or complete exhausting system to create a negative pressure isolation room for possible use with patients known or suspected of having Covid, TB, SARS or other infectious diseases.

LOW COST ISOLATION ROOM

An easy and economical solution for creating a negative pressure, isolation room. Simply roll the Air Purification system into a standard room, connect flexible ducting to the collar on the top of the unit for partial exhaust or total exhaust and vent the treated air to the exterior through a window or wall.

Room Air Changes Per Hour

Provides upto 25 room air changes per hour(ACH) depending on the volume.

Flexible Applications

The versatile Air Purification system can be used as a clean air recirculating unit or a negative pressure unit .

Small and Portable

Air Purification system can be rolled from one room to another and easily fits into areas with limited floor areas. Quiet Operation efficiency and is designed to work efficiently 24/7.

Low-High Clean Air Circulation Pattern

Room air, along with airborne contaminants, is drawn into the intake grille at the bottom while the purified air is discharged at a high velocity from the exhaust located at the top of the Air Purification system to generate a sweeping, low-to high air circulation pattern with adequate velocity to optimize the air in the room area for patient and staff.

Simple Maintenance

Entire Filtration Systems are easily accessible for replacement by our authorized maintenance engineers.

Air Purification system
Need Assistance?

Contact us for expert advice for your needs and budget.

SAFETY FEATURES

Air Purifier Safety Protection, Security, Rest Assured

Harmless

No Ozone Harm, No Radiation Harm

Non Toxic

Environment friendly materials, Non Toxic and no secondary pollution

Easy to Move

Body Handlebar, prevents hand slip

Anti Bump

Mellow and Full Body, High Quality acrylic panel

Air quality solutions can be implemented at home, offices, institutions etc. as air pollution is a generic problem that exists everywhere you go. Air Purification system provides an application-based solution so you can breathe pure air, everywhere you go.

Application

Hospital

Hospital

Dental Clinics, (ICUs),Isolation Wards etc

Schools

Schools

Class Rooms, Gyms, Auditoriums, etc

Restaurants

Restaurants

Hotels

Hotels

Board Rooms

Community Halls

Community Halls

amongst many other applications

CARBON — POTASSIUM PERMANGANATE FILTERS

Activated Carbon Efficiency

IT’S A GAS!

Particle Air Filters (including HEPAs& ULPAs) do not filter gases. A Particle Air Filter may capture particles that are out-gassing odors. ALL odors are gasses. We can filter most gases with adsorption or chemisorption filters.

ADSORPTION

Activated Carbon is the most common media of adsorption filters. Because activated carbon has a tremendous surface area and can adsorb most organic chemicals. Van der Waal’s Forces include the attraction and capture of gas or liquid molecules to the surface of a solid. Surface area is critical. 1 gram of activated carbon has over 5,382 ft2 of surface area. Just 3 lbs have over 160 acres of surface area.

ACTIVATED CARBON EFFICIENCY

Excellent Adsorption — 10–25% of weight.
Types of Odors: Adhesives, Antiseptics, Asphalt, Burned Foods & Fats, Charred Materials, Cigar and Cigarette Smoke, Cleaning Compounds, Decaying Materials, Diesel Fumes, Fish, Gasoline, Naptha, Ozone, Paint & Varnish, Pet, Sewer, Tar, Turpentine.
Some Specific Chemicals &Compounds :A — Acetic Acid, Acetic Anhydride, Acrylic Acid, Acrylonitrile, Amyl Acetate, Amyl Alcohol, Amyl Ether, Aniline.
B — Benzene, Bromine, Butanone, Butyl Acetate, Butyl Alcohol, Butyl Cellosolve, Butyl Chloride, Butyl Ether, Butyric Acid.
C — Camphor, Caprylic Acid, Carbolic Acid, Carbon Disulfide, Carbon Tetrachloride, Cellosolve, Cellosolve Acetate, Chlorobenzene, Chlorobuadiene, Chloroform, Chloronitropropane, Chloropicrin, Creosote, Cresol, Crotonaldehyde, Cyclohexane, Cyclohexanol, Cyclohexanone, Cyclohexene.
D — Decane, Dibromoethane, Dichlorobenzene, Dichlorodifluoromethane, Dichloroethane, Dichloroethylene, Dichloroethyl Ether, Dichloronitroethane, Dichloropropane, Dichlorotetrafluroethane, Diethyl Ketone, Dimethylaniline, Dimethyl sulfate, Dioxane, Dipropyl Keytone.
E — Ethyl Acetate, Ethyl Acrylate, Ethyl Alcohol, Ethyl Benzene, Ethyl Bromide, Ethyl Silicate, Ethylene Chlorohydrin, Ethylene Dichloride, Eucalyptol.
H — Heptane, Heptylene.
I — Indole, Iodine, Iodoform, Isophorone, Isopropyl Acetate, Isopropyl Alcohol, Isopropyl Ether.
K — Kerosene.
L — Lactic Acid.
M — Menthol, Mercaptans, Mesityl Oxide, Methyl Acrylate, Methyl• Butyl Ketone, Methyl Cellosolve, Methyl Cellosolve Acetate, Methyl Chloroform, Methyl Ethyl Ketone, Methyl Mercaptan, Methylcyclohexane, Methylcyclohexanol, Methylcyclohexane, Methylene Chloride, Monochlorobenzene, Monoflurotrichloromethane.
P — Palmitic Acid, Paradichlorobenzene, Pentanone, Perchloroethylene, Phenol, Propionic Acid, Propyl Acetate, Propyl Alcohol, Propyl Chloride, Propyl Ether, Propyl Mercaptan, Putrescine, Pyridine.
S — Skatole, Styrene Monomer, Sulfuric Acid.
T — Tetrachloroethylene, Toluene, Toluidine, Trichloroethylene, Trichloroethane, Turpentine.
U — Urea, Uric Acid.
V — Valerie Acid, Valericaldehyde.
X — Xylene.
Good Adsorption — 10–25% of weight.
Types of Odors: Animals, Anesthetics, Bleaching Solutions, Coal Smoke, Combustion, Corrosive Gases, Film Processing, Inorganic Chemicals, Mold, Solvents, Volatile Chemicals.
Specific Chemicals &Compounds :A — Acetone, Acrolein.
B — Borane, Butadiene, Butyraldehyde.
C — Chlorine.
D — Dichloromonofluormethane, Diethyl amine.
E — Ether, Ethyl Amine, Ethyl Chloride, Ethyl Ether, Ethyl Formate, Ethyl Inercaptan, Ethylene Oxide.
H — Hexane, Hexylene, Hexyne, Hydrogen Bromide, Hydrogen Cyanide, Hydrogen Iodide, Hydrogen Sulfide.
I — Isoprene.
M — Methyl Acetate, Methyl Alcohol, Methyl Bromide, Methyl Chloride, Methyl Ether, Methyl Formate.
N — Nitric Acid.
P — Pentane, Pentylene, Pentyne, Phosgene, Propionaldehyde.
V — Vinyl Chloride.

Activated Carbon is not effective on glycols, strong acids and bases, metals and some inorganics, such as lithium, sodium, iron, lead, arsenic, fluorine, and boric acid.

Chemisorption is a kind of Adsorption which involves a chemical reaction between the surface and the adsorbate.

Chemically bonded Adsorption.Potassium Permanganate is an inorganic chemical compound that is a strong oxidizing agent that doesn’t have a toxic end product. Excellent Chemisorption Acetic Acid, Aldehydes, Ethylene, Formaldehyde, Gluteraldehyde, Hydrogen Cyanide, Hydrogen Sulfide, Mercaptans, Nitric Oxide, Nitrogen Dioxide, Sulfur Dioxide, Sulfur Trioxide.

The combination of Activated Carbon and Potassium Permanganate provides the widest range of odor removal.

Air Purification system provides you an option of integrating an Carbon Activated – KMNO4 impregnated Heavy Duty FIlter

HIGHEST EFFICIENCY
ULPA FILTRATION
NEEDLE POINT BIPLOAR IONISATION – PLASMA AIR
  • Performance : ISO 6 to ISO 7
  • Airflow: 2000 cfm – ft3 /min (3398 m3/hr)
  • Coverage Area: Refer to Comparative Chart / ACH Data Sheet
  • Max Sound Levels: 58 dB(A)
  • Above max sound level is under partial choked conditions.
  • Average Sound Levels: 48-50 dB(A)
  • Filtration : U15 , ULPA 99.9995 down to 0.12 Micron
  • Best of Filtration Efficiency system
  • Airborne Pollutants adsorption system
  • Removal of Oxidant agents
  • Ultra fast Filtration system
  • Energy Saving Green – EC Fan
  • Airborne VOCs (Volatile Organic Compounds )are drastically reduced
  • Instantenous Elimination of H2O2 and APAs
  • Surface Decontimation due to Needle Point Bipolar Ionisation– PlasmaAir
  • Boon to Immuno Compromised Patients
  • Invitro Fertilization Centres - fast evacuation and removal of aldehydes like Formaldehydes and other VOCs
  • Essential in all Hematology and Transplant facilites

Ions: Mother Nature's Little Air Scrubbers.

NPBI (NEEDLE POINT BIPOLAR INONISATION) module is mounted on the Re-circulating / Supply side of Air Purification system. As air passes over the NPBI module, millions of positively and negatively charged ions are formed – just like in nature. These bipolar ions disperse into the occupied space, proactively attacking airborne contaminants where they cause the most problems for occupants. It is safe, low maintenance and long lasting.

Airborne particles are charged by the ions causing them to cluster and be caught in filters

As they divide to reproduce, bacteria and virus cells bond with oxygen ions and are destroyed

Odorous gases and aerosols oxidize on contact with oxygen ions and are neutralized

Oxygen ions cause a chemical reaction with VOCs breaking down their molecular structure